We produces distribution and power transformers between power values of 25kVA – 50MVA in accordance with the customers’ projects.
Distribution transformers are manufactured in compliance to customer requests, specifications and specified standards as one or three phased, oil immersed (with mineral, nonflammable oil or silicone), with natural cooling (ONAN), with forced cooling (ONANONAF), with open air expansion tanks, with completely sealed hermetic, gas cushioned hermetic, with on-load tap changers or off-circuit tap changers, with cable box or hood and with porcelain isolators or epoxy resin isolators.

DISTRIBUTION TRANSFORMERS

POWER TRANSFORMERS.DISTRIBUTION TRANSFORMERS.

Our products are manufactured in accordance with the requirements of the TS 267, IEC 60076, BS 171 standards. Each transformer that has been manufactured are shipped after they are subjected to the routine tests stipulated by the TS 267 and IEC 60076.

POWER TRANSFORMERS

POWER TRANSFORMERS.HERMETIC TRANSFORMERS.

These systems that are referred to as completely sealed systems are different from the types with oil expansion tanks because the transformer oil is completely sealed from the external environment. The advantages of these type of transformer is that the operational life of the oil that does not come into contact with the external environmental humidity is increased. As it is well known; the oil used in transformers with oil expansion tanks must be tested for humidity once every two years.

TRANSFORMERS WITH OIL TANKS

TRANSFORMERS WITH OIL TANKS.Transformer Oils Lasting asset performance

As the transformer heats up, the quantity of oil within it increases. The suitable environment for storing such expansions in the quantity of oil are the cylindrical tanks that have dimensions in appliance with project calculations. Due to the fact that these types of transformers are subject to external environmental conditions, the humidity of their oil must be continuously checked and the necessary oil drying procedures must be conducted when necessary.

STANDARDS SPECIFICATIONS

STANDARDS SPECIFICATIONS.WE PRODUCE BOILER.

Our products are manufactured in accordance with the requirements of the TS 267, IEC 60076, BS 171 standarts. Each transformer that has been manufactured are shipped after they are subjected to the routine tests stipulated by the TS 267 and IEC 60076.

BOILER

1. Waived boiler wall
2. Dial contact thermometer
3. Buchollz Relay
4. YG Isolator
5. AG Isolator
6. Oil Expansion Tank
7. Silica Gel and Box
8. Magnetic Oil Level Gauge
9. Terminal Box
10. Label
11. Oil Discharge Valve
12. Casters

ACTIVE SECTION

1. AG Isolator
2. YG Isolator
3. Commutator
4. Crane Connection Flange
5. Oil Filling Cap
6. Silica Gel Connection Flange
7. Yoke
8. Sellenoid
9. Commutator Connection Cables

NUVE INTERMEDIARY PRODUCTS

NUVE.INTERMEDIARY PRODUCTS.

NUVE, The Nucleus is manufactured with high quality cold drawn siliceous sheet metal. The width of the sheet metal is determined by the power output of the transformer to be produced and the quality of the sheet metal or its magnetic conductivity is expressed in Gauss units.

Our company uses sheet metal produced in western Europe that has high levels of magnetic conductivity. The sheet metal that arrives at our factory is accepted after the approval of our quality control department. The sheet metal is later cut into the dimensions required by the project in accordance with requirements of the power and voltage of the transformers being produced and are later subjected to the nucleus arranging process.

SELENOIDS

SELENOIDS.WINDINGS; AG COIL and YG COIL.

This section referred to as the solenoid or the coil is comprised of 2 main pieces.

1) AG COIL: this copper coil with varying dimensions is sometimes spun with flat copper or copper tape in accordance with technological innovations. The aluminum or copper materials that are spun are in direct contact with the AG bushings. The transformer output voltage and power are created on these coils.
2) YG COIL: these coils are spun over the AG Coils with round isolated copper wire in dimensions between 0,3 mm – 3,00 mm as needed by the power and voltage of the transformers. Various isolation materials are installed between this coil to attain isolation and cooling.

Furthermore, the commutator connection flanges are fixed in positions on the coil suitable for the project and can deactivate certain sections of the coil.

Contact Us? Please click here